Tools menu: Difference between revisions

From USC Nanofab Wiki
Jump to navigation Jump to search
No edit summary
No edit summary
Tag: Reverted
Line 1: Line 1:
__NOTOC__
{{tool2|{{PAGENAME}}
|picture=Blue M oven big.jpg
|type = Thermal Processing
|super = Chandan Ramakrishnaiah
|super2 = Shivakumar Bhaskaran
|phone = (213) 551 6726
|location = Advanced Photo bay
|email =  <!-- Add USC email if needed, e.g. chandan@usc.edu or leave blank -->
|description = Blue M OV-12A Large Drying Oven for baking, curing, and low-temperature annealing up to 260°C
|manufacturer = Blue M (now part of Thermal Product Solutions)
|materials = Substrates, photoresist, polymers, glass, metals (check restrictions per process)
|toolid =  <!-- Add your internal tool ID if you have one, or leave blank -->
}}
__TOC__


{| class="wikitable" style="width:max-content;"
== About ==
|
[[File:Blue M oven big.jpg|thumb|300px|Blue M OV-12A Large Drying Oven in Advanced Photo Bay]]
=== Tool Categories ===
* [[#Anneal & Furnace|Anneal & Furnace]]
* [[#Deposition|Deposition]]
* [[#Dry Etching & Plasma Cleaning|Dry Etching & Plasma Cleaning]]
* [[#Lithography|Lithography]]
* [[#Metrology|Metrology]]
* [[#Packaging & Mechanical Tooling|Packaging & Mechanical Tooling]]
* [[#PCB Processing|PCB Processing]]
* [[#Wet Process|Wet Process]]
|}


== Anneal & Furnace ==
'''Process:''' This is a large-capacity forced-air convection drying oven designed for reliable, uniform heating at moderate temperatures. It is commonly used for baking photoresists, curing polymers, drying samples after wet processing, outgassing, or low-temperature annealing in a clean, controlled air environment.
* [[RTA (Rapid Thermal Annealer)]]
* [[Cascade Tek vacuum oven]]
* [[Blue M furnace big]]
* [[Blue M furnace little]]
* [[Narco vacuum oven]]


== Deposition ==
'''Hardware:''' Forced-air circulation with adjustable fan speed for excellent temperature uniformity. Stainless steel interior for cleanroom compatibility and easy cleaning. Digital temperature controller with over-temperature protection. Shelving system for multiple samples or larger substrates. Door with observation window and gasket seal.


=== CVD (Chemical Vapor Deposition) ===
'''Atmosphere:'''
* [[Oxford PECVD]]
* Ambient air (forced convection)
* [[Veeco ALD]]
* No vacuum or special gases (for inert or forming gas anneals, use RTA or other tools)
* Optional N₂ purge if modified (not standard – confirm if equipped)


=== PVD (Physical Vapor Deposition) ===
'''Applications:'''
* [[Angstrom Evaporator]]
* Post-bake and hard bake of photoresists (e.g., 90–180°C)
* [[CHA Evaporator]]
* Curing of spin-on dielectrics, polyimides, or adhesives
* [[KJL Evaporator]]
* Drying wafers/substrates after rinse or solvent clean
* [[Temescal Metal e-beam evaporator]] (Not in service)
* Low-temperature outgassing or degassing
* [[KJL Sputter]]
* Gentle thermal treatment of delicate samples
* Aging or stability testing of materials


== Dry Etching & Plasma Cleaning ==
'''Usage:''' Load samples on shelves, set temperature and time via controller, allow stabilization, run process. Use timer or manual monitoring. Cool down before opening door to avoid thermal shock or contamination. Follow SOP for loading/unloading and cleaning.


=== Etchers ===
== Detailed Specifications ==
* [[Oxford DRIE]]
* Model: Blue M OV-12A
* [[Oxford DRIE-ALE]] (being commissioned)
* Location: Advanced Photo bay
* [[Oxford III-V]]
* Substrate size: Flexible (wafers up to 8–12", cassettes, trays, or multiple pieces – check interior dimensions)
* [[Oxford RIE]]
* Temperature range: Ambient to 260°C
* [[XeF2 etcher]]
* Temperature control: Digital PID controller with uniformity typically ±2–5°C across chamber (depending on load)
* Heating: Electric elements with forced-air circulation
* Features: Over-temperature safety cutoff, adjustable shelves, observation window, cleanroom-compatible design
* Restrictions: Max 260°C (not for high-temperature processes); avoid volatile/corrosive chemicals that could damage interior or contaminate other users
* Other: Large interior volume suitable for batch processing or bigger substrates


=== Plasma Cleaning / Ashing ===
== Documentation ==
* [[Tegal O2 Plasma Asher]]
* [[:File:Blue M OV-12A Drying Oven SOP v1.pdf|SOP – Standard Operating Procedure]]
* [[Tegal Plasma]] (not in operation)
* Training required – contact lab staff (Chandan Ramakrishnaiah or Shivakumar Bhaskaran)
* [[YES O2 Plasma]]


== Lithography ==
== Recipes & Data ==
* Standard Processes: Common bakes include:
  * Photoresist soft bake: 90–110°C
  * Post-exposure bake (PEB): 100–130°C
  * Hard bake: 120–180°C
  * Curing of SU-8 or polyimide: 150–250°C
* Process Control: Verify temperature uniformity with thermocouple checks if needed. Monitor for contamination (e.g., particles) after use.
* Notes: Allow pre-heat stabilization time (30–60 min) for best uniformity. Use foil or trays to protect shelves from spills.


=== E-beam and Laser ===
<!-- Optional: Add more images here if you have interior views, shelving, control panel, or example sample setups. -->
* [[Raith EBL]]
* [[Heidelberg DWL]]
 
=== UV Mask Aligners ===
* [[Aligner A (MJB3)]]
* [[Aligner B (MJB3)]]
* [[Aligner C (MJB4)]]
* [[Aligner D (MA BA6 Gen4)]]
 
== Metrology ==
 
=== Assorted Metrology ===
* [[4-point Probe]]
* [[Dektak profilometer]]
* [[Ellipsometer]]
* [[Filmetrics F20]]
 
=== Microscopes ===
* [[Desktop SEM]]
* [[Nikon LV 150 optical microscope]]
* [[Max ERB optical microscope]]
* [[Zeiss optical microscope]]
* [[Nikon SMZ-10A optical microscope]]
* [[Nikon optical microscope]]
 
== Packaging & Mechanical Tooling ==
 
=== Wafer and Die Processing ===
* [[Ball & Wedge bonder]]
* [[Dicing Saw]]
* [[Mini Polisher]]
* [[LatticeAx Cleaver]]
* [[FlipScribe Cleaver]]
* [[Vacuum Bag Sealer]]
 
== PCB Processing ==
* [[LPKF PCB mill]]
* [[LPKF electroplater]]
 
== Wet Process ==
 
=== Fume Hoods & Stations ===
 
* Solvent Fume Hood (Metrology bay)
** [[Heated ultrasonic bath]] (Solvent hood)
** [[Torrey Pines hot plate]] (Solvent hood)
** Solvent drains
** N2 sprayers
 
* Acid Fume Hood – Left (Etch bay) – Piranha & Nanostrip allowed
** [[Imtec Accubath]] (Acid left)
** Quick-dump-rinse tank (QDR)
** DI water tap
** N2 gun
 
* Acid Fume Hood – Right (Etch bay) – No Piranha/Nanostrip
** [[Imtec Accubath]] (Acid right)
** [[Torrey Pines hot plate]] (Acid right – left & right units)
** Quick-dump-rinse tank (QDR)
** DI water tap
** N2 sprayer
 
* Resist Fume Hood (Advanced Photo bay)
** [[Laurell Spinner]] (left & right)
** [[Apogee Bake Plate]] (1–4)
 
* Base & Developer Fume Hood – Left (Advanced Photo bay)
** [[Imtec Accubath]] (Developer left)
** [[Torrey Pines hot plate]] (Developer left)
** Quick-dump-rinse tank (QDR)
** DI water tap
** N2 sprayer
 
* Base & Developer Fume Hood – Right (Advanced Photo bay)
** [[Imtec Accubath]] (Developer right)
** [[Torrey Pines hot plate]] (Developer right)
** Quick-dump-rinse tank (QDR)
** DI water tap
** N2 sprayer
 
* E-beam Resist Fume Hood (Photo bay)
** [[Headway Spinner]] (left & right)
** [[Apogee Hot Plate]] (left & right – ebeam)
** Ultrasonic heated bath
** [[Torrey Pines hot plate / stirrer]] (ebeam hood)

Revision as of 14:26, 2 February 2026

Template:Tool2

About

Blue M OV-12A Large Drying Oven in Advanced Photo Bay

Process: This is a large-capacity forced-air convection drying oven designed for reliable, uniform heating at moderate temperatures. It is commonly used for baking photoresists, curing polymers, drying samples after wet processing, outgassing, or low-temperature annealing in a clean, controlled air environment.

Hardware: Forced-air circulation with adjustable fan speed for excellent temperature uniformity. Stainless steel interior for cleanroom compatibility and easy cleaning. Digital temperature controller with over-temperature protection. Shelving system for multiple samples or larger substrates. Door with observation window and gasket seal.

Atmosphere:

  • Ambient air (forced convection)
  • No vacuum or special gases (for inert or forming gas anneals, use RTA or other tools)
  • Optional N₂ purge if modified (not standard – confirm if equipped)

Applications:

  • Post-bake and hard bake of photoresists (e.g., 90–180°C)
  • Curing of spin-on dielectrics, polyimides, or adhesives
  • Drying wafers/substrates after rinse or solvent clean
  • Low-temperature outgassing or degassing
  • Gentle thermal treatment of delicate samples
  • Aging or stability testing of materials

Usage: Load samples on shelves, set temperature and time via controller, allow stabilization, run process. Use timer or manual monitoring. Cool down before opening door to avoid thermal shock or contamination. Follow SOP for loading/unloading and cleaning.

Detailed Specifications

  • Model: Blue M OV-12A
  • Location: Advanced Photo bay
  • Substrate size: Flexible (wafers up to 8–12", cassettes, trays, or multiple pieces – check interior dimensions)
  • Temperature range: Ambient to 260°C
  • Temperature control: Digital PID controller with uniformity typically ±2–5°C across chamber (depending on load)
  • Heating: Electric elements with forced-air circulation
  • Features: Over-temperature safety cutoff, adjustable shelves, observation window, cleanroom-compatible design
  • Restrictions: Max 260°C (not for high-temperature processes); avoid volatile/corrosive chemicals that could damage interior or contaminate other users
  • Other: Large interior volume suitable for batch processing or bigger substrates

Documentation

Recipes & Data

  • Standard Processes: Common bakes include:
 * Photoresist soft bake: 90–110°C
 * Post-exposure bake (PEB): 100–130°C
 * Hard bake: 120–180°C
 * Curing of SU-8 or polyimide: 150–250°C
  • Process Control: Verify temperature uniformity with thermocouple checks if needed. Monitor for contamination (e.g., particles) after use.
  • Notes: Allow pre-heat stabilization time (30–60 min) for best uniformity. Use foil or trays to protect shelves from spills.